ApartmentBlock
Building with multiple apartments, bigger than a multi family house.
MultiFamilyHouse
Building made for several households, generally over several storeys.
RowHouse
(also called terraced house) Building made for one household, part of a row of identical or mirror-image houses sharing side walls.
SingleFamilyHouse
Isolated building made for one household.
numberOfRooms
[int] number of separated rooms other than a circulation space in the building unit
ownerName
[String] name of the owner
ownershipType
[CodeList] Type of organisations, associations, businesses etc. that owns the building (e.g. individual, public authority, property
management company, non-profi t organisation etc.)
usedArea
[m²] usable floor area (or net internal area) of the building unit
occupiedBy
has
technologyType
Cogeneration technology (e.g. Stirling motor, engine motor, turbine)
Conditioned
Actively heated, or cooled or both (inhabited)
Unconditioned
Neither heated nor cooled (uninhabited)
None
No building part (it means "flat roof" if related to atticType, or "no basement" if related to basementType)
absorptance
Effectiveness of a surface in absorbing radiant energy
reflectance
Effectiveness of a surface in reflecting radiant energy
transmittance
Effectiveness of a construction in transmitting radiant energy
uValue
[W/m2.K] overall heat transfer coeffi cient. It represents the heat flux transfer through a construction, normalized by the construction
surface and the difference of temperature across the construction, at steady state.
layer
Reference to layers that comprise this construction. Multiple LayerId's order is important and specifi es the layering of the layer's referenced
materials. The fi rst Surface/AdjacentSpaceId entered will determine how the referenced construction layers are ordered with the fi rst
construction layer being in contact with the outside or 2nd Surface/AdjacentSpaceId listed and the last layer in contact with the fi rst
Surface/AdjacentSpaceId listed
orientation
If orientation == true the layers are used in the specifi ed order (see Construction), otherwise in reverse order.
baseConstruction
Reference to the Construction being used.
controlledVariable
setPoint
dayType
[CodeList] Type referring to a day categorization (e.g weekDay, weekEnd)
schedule
CustomDay1
Customized day type for a specifi c use - 1
CustomDay2
Customized day type for a specifi c use - 2
Holiday
Monday
OtherDay
All days other than those already specifi ed in the ScheduleLoD3 object
Saturday
SummerDesignDay
"Extrem summer" day used for the sizing and design of HVAC Systems in summer condition
Sunday
Thursday
Tuesday
Wednesday
WeekDay
Monday to Friday
WeekEnd
Saturday and Sunday
WinterDesignDay
"Extrem winter" day used for the sizing and design of HVAC Systems in winter condition
numberOfBath
number of baths in a given building unit/zone
numberOfShower
number of showers in a given building unit/zone
numberOfWashBasin
number of wash basin in a given building unit/zone
waterStorageVolume
Building
Building with a unique energy conversion system.
Dwelling
One energy conversion system per dwelling
GroupOfBuildings
Group of Building with a unique energy conversion system.The energy distribution runs between the buildings.
Room
One energy conversion system per room
Staircase
One energy conversion system per building stair-case, with a distribution system supplying vertically the premises of the different storeys
Storey
One energy conversion system per storey, with a distribution system supplying horizontally the premises of whole storey.
networkId
networkNodeId
electricalPower
[W] nominal electrical power of the electrical appliance
heatLosses
[W] average heat losses of the electrical appliance
name
[String] name of the electrical appliance
percentage
[Scale] Fraction of incident radiant flux of a given wavelength range that is absorbed by a construction surface (emissivity)
surface
[CodeList] Considered surface of the construction
wavelengthRange
[CodeList] Wavelength range of the incident radiant flux, for which the emittance ratio is defi ned
Cooking
DomesticHotWater
ElectricalAppliances
Lighting
OtherOrCombination
SpaceCooling
Processes of cooling down the space.
SpaceHeating
Processes of heating up the space.
Ventilation
installedNominalPower
[HeatExchangeType] Total nominal power of the end use units
number
[Integer] Number of similar end use units in the considered building zone
type
Convector
FanCoil
RadiantCeiling
RadiantFloor
Radiator
co2EmissionFactor
[gCO2/kWh]
equivalent
c
arbon dioxide
emitted by
the combustion of 1 kWh
energy carrier
energyDensity
[unit] amount of energy stored in a given volume of the energy carrier
Different units are typical for different fuel types (gas VS. wood VS. oil etc.)
primaryEnergyFactor
[-] Ratio of Final energy over Primary Energy
type
[CodeList] Name of Energy Carrier
ChilledAir
ChilledWater
Coal
Electricity
FuelOil
HotAir
HotWater
NaturalGas
Propane
Steam
WoodChips
WoodPellets
effi ciencyIndicator
Reference effi ciency ratio used to quantify the system effi ciency (e.g. COP, EER, W/(m3/h) )
installedNominalPower
[W] Total nominal power of the energy conversion system
model
[String] Model reference of the energy conversion system
nominalEffi ciency
[Measure] Nominal ratio of energy output to input, according to manufacturer
number
[Integer] Number of similar energy conversion units which constitutes the energy conversion system
productAndInstallationDocument
[External Reference] External documents adding information on the energy conversion system product and its installation.
yearOfManufacture
[Year] Year of manufacture of the energy conversion system (its main equipments)
has
consumes
installedIn
coverageRatio
coveredBy
endUse
[CodeList] Category of end use related to an energy use.
energyAmount
[TimeSeries] Time-depending amount of useful energy, corresponding to a specifi c end-use. It can be constituted of simulated or
monitored data, with different time resolutions (see TimeSeries model).
energyDistribution
distributionPerimeter
storageSystem
energySupply
endUseUnit
energyAmount
[TimeSeries] Time-depending amount of energy source, consumed by an energy conversion system. It can be constituted of simulated or
monitored data, with different time resolutions (see TimeSeries model).
energyCarrier
[CodeList] Energy form containing energy
coverage
endUse
[CodeList] Category of end use related to an energy use.
energyAmount
[TimeSeries] Time-depending amount of energy supply. It can be constituted of simulated or monitored data, with different time resolutions
(see TimeSeries model).
medium
producedBy
coverage
operationSchedules
isVentilated
Indicates whether a gas-layer is ventilated
rValue
Resistance of material
thickness
hemisphericalEmittance
Hemispherical emittance
hemisphericalReflectance
Hemispherical reflectance
hemisphericalTransmittance
Heminpherical transmittance
normalIncidenceEmittance
Emittance in surface normal direction
normalIncidenceReflectance
Reflectance in surface normal direction
normalIncidenceTransmittance
Transmittance in surface normal direction
numberOfPanes
Number of glazing panes
convectiveFraction
[Scale] ratio of convective heat exchange over total heat exchange
latentFraction
[Scale] ratio of latent heat exchange over total heat exchange
radiantFraction
[Scale] ratio of radiant heat exchange over total heat exchange
totalValue
[Measure] Total heat exchange value (positve for heat source, negative for heat sink/cool source)
carnotEffi ciency
heatSource
AmbientAir
Aquifer
ExhaustAir
HorizontalGroundCollector
VerticalGroundCollector
residenceType
type
LoneAdult
MultiFamily
OneFamily
PensionerCouple
UnrelatedAdults
Vacant
WorkerCouple
url
Specifi es location of the image. From X3D specifi cation: The texture is read from the URL specifi ed by the url fi eld. When the url fi eld
contains no values, texturing is disabled. Browsers shall support the JPEG and PNG image fi le formats. In addition, browsers may support
other image formats (e.g. CGM) which can be rendered into a 2D image. Support for the GIF format is also recommended (including
transparency).
repeatS
From X3D specifi cation: If repeatS is TRUE, the texture map is repeated outside the [0.0, 1.0] texture coordinate range in the S direction
so that it fi lls the shape. If repeatS is FALSE, the texture coordinates are clamped in the S direction to lie within the [0.0, 1.0] range.
repeatT
From X3D specifi cation: If repeatT is TRUE, the texture map is repeated outside the [0.0, 1.0] texture coordinate range in the T direction so
that it fi lls the shape. If repeatT is FALSE, the texture coordinates are clamped in the T direction to lie within the [0.0, 1.0] range.
AverageInPrecedingInterval
AverageInSucceedingInterval
ConstantInPrecedingInterval
ConstantInSucceedingInterval
Continuous
Discontinuous
InstantaneousTotal
MaximumInPrecedingInterval
MaximumInSucceedingInterval
MinimumInPrecedingInterval
MinimumInSucceedingInterval
PrecedingTotal
SucceedingTotal
contains
layerComponent
areaFraction
Percentage (1 - 100%) of the layer area that the referenced Material is made from.
thickness
Thickness of a layer component.
material
Reference to the corresponding Material
time
value
heatRecovery
recuperationFactor
Air
Steam
Water
internGains
[Measure] Heat power exchanged by the room occupants and non-HVAC devices to the room (positive for heat source, negative for heat
sink/cool source)
numberOfOccupants
[Integer] number of occupants of the considered zone/building unit
occupancyRate
[_Schedule] Schedule of room/zone occupancy (0 while empty, 1 while occupied with the specifi ed fullnumber of occupant, between 0 and
1 during partial occupancy)
occupantType
Type of occupants of a premises
consiststOf
OthersOrCombination
Patients
Residents
Students
Visitors
Workers
conductivity
Conductivity of material
density
Density of material
permeance
The rate water vapor is allowed through a surface
porosity
The ratio of the total amount of void space in a material (due to poses, small channels, and so on) to the bulk volume occupied by the
material.
specifi cHeat
Specifi c heat of material
controls
endUse
operationTime
yearlyGlobalEffi ciency
belongs
produced
Corporation
Government
A government-sponsored organization owns the premises.
NonOccupantPrivateOwner
NonProfi tOrganisation
OccupantPrivateOwner
OtherOrCombination
PropertyManagementCompany
cellMaterialType
current
voltage
batteryTechnology
powerCapacity
percentage
[Scale] Fraction of incident radiant flux of a given wavelength range that is reflected by a construction surface (reflectivity)
surface
[CodeList] Considered surface of the construction
wavelengthRange
[CodeList] Wavelength range of the incident radiant flux, for which the reflectance ratio is defi ned
timeInterval
Interval of time between two consecutive time-depending values
values
values of the time series
MainResidence
(or primary residence) Residence where a household lives for the greatest amount of time.
SecondaryResidence
Residence where a household lives part time or less than the majority of the calendar year.
Vacant
Residence where nobody lives.
averageValue
[Measure] average variable value
dailyUsageEndingTime
ending time of daily usage during day of usage
dailyUsageStartingTime
starting time of daily usage during day of usage
idleValue
[Measure] Variable value outside usage time (e.g. set-back temperature)
usageDaysPerYear
[Integer] number of days per year of usage
usageValue
[Measure] Variable value during usage time (e.g. set-point temperature)
dailySchedule
Schedule over a one day period (from 0:00 to 24:00)
timeDependingValues
[TimeSeries]
maximumCoverRatio
[Scale] Maximum fraction of the considered opening which can be covered with the shading device.
name
[String] Name of the Shading system
transmittance
Effectiveness of the shading device in transmitting an incident radiant flux of a given wavelength range
technologyType
[String] Solar thermal system technology
area
[Area] Area of the surface component, part of the related thermal boundary surface.
isGroundCoupled
[Boolean] True if one side of the surface component is against the ground.
isSunExposed
[Boolean] True if one side of the surface component is outdoor, with a non-null sky view factor.
relates
adjacentTo
Inside
Indoor surface
Outside
Outdoor surface
azimuth
Azimuth angle of the normal surface vector.By convention:- azimuth = 0 for north orientation.- Horizontal surface have a azimuth = 0.
inclination
Inclination angle of the normal surface vector.By convention, inclination = 0 for horizontal plane.
type
Topological classifi cation of the thermal boundary surfaces
composedOf
partOf
correspondsTo
OuterWall
Vertical thermal boundary surface with one side facing outdoor (facade)
SharedWall
Vertical thermal boundary surface delimiting two different buildings.
FlatRoof
Thermal boundary surface corresponding to a flat roof boundary surface
PitchedRoof
Thermal boundary surface corresponding to a pitched roof boundary surface
CellarCeiling
Upper horizontal thermal boundary surface of the basement floor.
BasementFloor
Lower horizontal thermal boundary surface of the basement floor.
TopCeiling
Ceiling of the highest storey of the zone.
isCirculation
medium
nominalFlow
returnTemperature
supplyTemperature
thermalLossesFactor
preprarationTemperature
medium
thermalLossesFactor
U*A
volume
additionalThermalBridgeUValue
Transmission heat loss contribution [W/m².K] of the thermal bridges of the thermal zone shell to the overall UValue.
cooledFloorArea
Actively cooled floor area [m²]
effectiveThermalCapacity
Thermal capacity [Wh/K] of the zone including the contributing construction layers and zone fournitures.
heatedFloorArea
Actively heated floor area [m²]
indirectlyHeatedAreaRatio
[fi nd precise defi nition]
infi ltrationRate
Air change rate [1/h] due to air leakage of the zone shell.
boundedBy
relates
acquisitionMethod
[String] for variable acquisition (e.g. simulation, measured)
interpolationType
[CodeList] Mathematical rule required for the variable interpolation, defi ned in WaterML:http://def.seegrid.csiro.au/sissvoc/ogc-def/
resource?uri=http://www.opengis.net/def/waterml/2.0/interpolationType/
qualityDescription
[String] Description of the data quality (e.g. bad, average, good, excellent)
source
[String] Designation of the data source
uom
[UnitOfMeasure] Unit of measure of the variable
variableLabel
[String] Name of variable
percentage
[Scale] Fraction of incident radiant flux of a given wavelength range that is transmitted through the constructionl (transmissivity)
wavelengthRange
[CodeList] Wavelength range of the incident radiant flux, for which the transmittance ratio is defi ned
coolingSchedule
Temperature schedule [°C] of the active cooling inside the usage zone.
heatingSchedule
Temperature schedule [°C] of the active heating inside the usage zone.
usageZoneClass
Usage class of the zone.
usedArea
Used floor area [m²].
usedFloorNumbers
List of the number of floors part of the usage zone (0 = ground level).
ventilationSchedule
Air change rate [1/h] schedule of the ventilation system inside the usage zone.
contains
what is meant with that ?
occupiedBy
has
Solar
Solar radiation spectrum (Wavelength range: mainly 300 nm – 2500 nm), also called short-wave radiation.
IR
Infrared spectrum (Wavelength range: 700 nm – 1000 mm), also called long-wave radiation. Range of thermal radiation exchanges close
to ambient temperature.
Visible
Visible light spectrum (Wavelength range: 400 nm – 800 nm)
Total
Total electromagnetic spectrum
_AbstractBuilding
Application Domain Extension Energy of CityGML object AbstractBuilding
_BoundarySurface
Application Domain Extension Energy of CityGML object BoundarySurface
_CityObject
Se
_Opening
Application Domain Extension Energy of CityGML object Opening
_Schedule
_SolarEnergySystem
Either solar thermal or photovoltaic system, using solar energy to generate heat or electricity
_StorageSystem
System storing energy. A same storage may store the energy of different end-users and different end-use.
_TimeSeries
Consistent series of time-depending values.
Absorptance
Effectiveness of a material surface in absorbing an incident radiant flux of a given wavelength range
AbstractMaterial
Abstract superclass for all Material classes. A Material is a homogeneous substance that can be used to form elements.
Boiler
Closed vessel in which water is heated.
BuildingType
Building classifi cation based on building size, situation and function
BuildingUnit
Part of usage zone, such as dwelling or workplace, which is related to a single occupant entity (e.g. household, company).
CombinedHeatPower
Also called cogeneration. Heat engine or power station generating electricity and useful heat at the same time
ConditioningType
Conditioned status of a building part
Construction
A Construction is a combination of layers, such as a wall or a roof, delimited by two parallel surfaces.
ConstructionOrientation
Determines the usage of Construction in terms of the Layer order.
ControlType
(Not used anymore in Energy ADE v0.6)
DailySchedule
Schedule over a one day period (from 0:00 to 24:00)
DayType
Type referring to a day categorization
DHWFacilities
Facilities for domestic hot water usage.
DistributionType
Classifi cation referring to energy distribution art between the energy conversion system and the end-use place.
DistrictNetworkSubstation
ElectricalAppliances
Non-HVAC electrical devices/appliances inside the building unit or building zone.
ElectricalResistance
Emittance
Effectiveness of a material surface in emitting an incident radiant flux of a given wavelength range
EndUseType
Category of end use related to a building energy use
EndUseUnit
Final device(s) which deliver the required end-use to the end-user in his end-use place (e.g. radiators or convectors for heating etc.)
EndUseUnitType
Type of end-use units, delivering the required useful energy at the end-use place
EnergyCarrier
Energy form containing the energy (e.g. fuel, electricity etc.)
Distinction between EnergyCarrier and EnergySource should be made (see https://en.wikipedia.org/wiki/
Primary_energy )
EnergyCarrierType
Name of energy form containing energy
EnergyConversionSystem
System
which converts an
energy source
in
the energy
required
to satisfy the end-use (or to feed the networks).
EnergyCoverage
Determine the level of energy coverage (may be time depending) by a given operation mode of an energy conversion system.
EnergyDemand
Useful energy required to satisfy a specifi c end-use, such as heating, cooling, domestic hot water etc.
EnergyDistributionSystem
System which delivers the energy inside the building, from the place of energy production to the place of end-use. It consists then in the
storage (including battery/tank and pipe volumes), the circulation pumps, the distribution pipes and the end use units (radiators, fan coils
etc.).
EnergySource
Energy being consumed by an energy conversion system. It can be non-renewable (fuel) or renewable. It may be produced by another
energy conversion system.The Energy produced by a conversion system and fed-in in the electrical grid or district network is also
considered as EnergySource, since it also aims to be consumed by an energy conversion system, in another building (building block)
EnergySupply
Part of the energy produced by the energy conversion systems which is used to satisfy the end-use demand of a city object.
Facilities
Facilities and Appliances inside the usage zone or building unit, which consumes and dissipate energy.
Gas
Gaseous material
Glazing
Transparent material
HeatExchangeType
Contributions of the different types of heat or cool exchange (convective, radiant and latent)
HeatPump
HeatSourceType
Household
Household is a group of persons living in the same dwelling, in the case where occupant type is residents.
HouseholdType
Classifi cation of Household, according with their family structure, person number and generation
ImageTexture
This is an X3D element to map a texture to this material. From X3D specifi cation: The ImageTexture node defi nes a texture map by
specifying an image fi le and general parameters for mapping to geometry. Texture maps are defi ned in a 2D coordinate system (s, t) that
ranges from [0.0, 1.0] in both directions. The bottom edge of the image corresponds to the S-axis of the texture map, and left edge of the
image corresponds to the T-axis of the texture map. The lower-left pixel of the image corresponds to s=0, t=0, and the top-right pixel of the
image corresponds to s=1, t=1.
InterpolationType
Mathematical rule required for the variable interpolation, defi ned in WaterML:http://def.seegrid.csiro.au/sissvoc/ogc-def/resource?uri=http://
www.opengis.net/def/waterml/2.0/interpolationType/
IrregularTimeSeries
Defi ned as opposite of a regular time series, the value in the time series follows a temporal sequence, but the measurements might not
happen at a regular time interval (http://www-01.ibm.com/support/knowledgecenter/SSCRJU_3.0.0/
com.ibm.swg.im.infosphere.streams.timeseries-toolkit.doc/doc/timeseries-regular.html)
Layer
A Layer is a combination of one of more materials, references via a LayerComponent.
LayerComponent
MeasurementPoint
MechanicalVentilation
MediumType
Occupancy
Aggregated group of occupants of a premises (e.g. residents, workers, visitors)
OccupantType
Type of occupants of a premises
OpaqueMaterial
Opaque material.
OperationMode
Operation mode details the operation of the energy conversion system for a specifi c end-use and operation time.
OwnershipType
The type of organization, association, or business, that owns the premises.
PhotovoltaicSystem
PowerDistributionSystem
PowerStorageSystem
Reflectance
Effectiveness of a material surface in reflectiing an incident radiant flux of a given wavelength range
RegularTimeSeries
Series of time-depending values, regularly spaced with a constant interval of time
ResidenceType
Designation related to the amount of time a household lives at a residence.
ScheduleLoD0
Lowest Level of Detail of the schedule representation, consisting in a constant value
ScheduleLoD1
Level of Detail 1 of the schedule representation, consisting in a two-state schedule related to a usage time
ScheduleLoD2
Level of Detail 2 of the schedule representation, consisting in a set of daily schedules associated to recurrent day types (weekday,
weekend etc.).
ScheduleLoD3
Highest Level of Detail of the schedule representation, consisting in a Timeseries
ShadingType
Shading system of the considered opening
SolarThermalSystem
System converting solar energy in heat (hot water)
SurfaceComponent
Part of the thermal boundary surface corresponding to an homogeneous construction component (e.g. windows, wall, insulated part of a
wall etc.)
SurfaceSide
Surface side of the construction
ThermalBoundarySurface
Quasi-coplanar surfaces bounding the thermal zone. They may be linked to the gml:BoundarySurface when possible, but not necessary
(e.g. cellar ceiling or top storey ceiling in the case of LOD1-3)
ThermalBoundarySurfaceTypeType
Topological classifi cation of the thermal boundary surfaces
ThermalDistributionSystem
ThermalStorageSystem
ThermalZone
Zone of a building with a homogeneous temperature, which serves as unit for the building heating and cooling simulation. It is a semantic
object which may be or not related to a geometric entity (e.g. Building, Room).
TimeValuesProperties
Information and properties of a given variable.
Transmittance
Effectiveness of a construction in transmitting an incident radiant flux of a given wavelength range
UsageZone
Zone of a building with homogeneous usage type.
WavelengthRangeType
Part of electromagnetic spectrum, corresponding to a range of radiation wavelength
CLASS
ATTRIBUTES
DESCRIPTION
MODIFIER
COMMENT/SUGGESTION